MC25

Capacity of 25 m3/h

Technical Overview

MC25 is primarily intended for small and medium-sized hospitals. The gas cylinder pressure is regulated in two steps. The change-over between operating side and reserve side is made automatically without any differences in the operating pressure. The alarm signal comes from the pressure switches to the alarm unit. The alarm signals from the alarm unit can be forwarded directly to a monitoring desk.
Function control and service can be carried out without interruption in the gas supply
MC25 includes the following components:
Gas manifold MC25
Gas alarm including power supply
Evacuating kits for collecting pipe
Shut-off valve for distribution line
HP filters
Collecting pipe for 2×1 cylinder

Product Information

Item No.
Description
0732300
Denomination: MC25 – 2×1, Gas: O2, PRV: Manual activation, Signilization: Alarm TMA6703
0732301
Denomination: MC25 – 2×1, Gas: Air, PRV: Manual activation, Signalization: Alarm TMA6703
0732302
Denomination: MC25 – 2×1, Gas: N2O, CO2, PRV: Manual activation, Signalization: Alarm TMA6703
0732300
Denomination: MC25 – 2×1, Gas: O2, PRV: Manual activation, Signilization: Alarm TMA6703
0732301
Denomination: MC25 – 2×1, Gas: Air, PRV: Manual activation, Signalization: Alarm TMA6703
0732302
Denomination: MC25 – 2×1, Gas: N2O, CO2, PRV: Manual activation, Signalization: Alarm TMA6703
Regional information available in your language at
GCEGROUP.COM

Technical

Gases
O2, Air, N2, N2O, CO2, (all medical gases)
Nominal flow
25 m3/h
Inlet nominal pressure
200 bar (20 000 kPa)
Outlet nominal pressure
4,5 bar (setting range 0,5–6 bar)
Intermediate nominal pressure
12 bar (setting range 9–16 bar)
Inlet connection
W21,8×1/14"M
Outlet connection
G1/2"M + soldering piece pipe ø 10, ø 15 mm
Outlet pressure relieve valve
6,8 bar
Intermediate pressure relieve valve
17 bar
Pressure relieve valve pipe dimension
ø 15 mm
Regulatory status
Complies with Medical Devices Directive 93/42/EEC, EN ISO 7396-1 (Central Gas Supply Systems), EN 60601-1-2 (Electromagnetic compatibility), present SIS HB 370 and HTM 02-01
Gases
O2, Air, N2, N2O, CO2, (all medical gases)
Nominal flow
25 m3/h
Inlet nominal pressure
200 bar (20 000 kPa)
Outlet nominal pressure
4,5 bar (setting range 0,5–6 bar)
Intermediate nominal pressure
12 bar (setting range 9–16 bar)
Inlet connection
W21,8×1/14"M
Outlet connection
G1/2"M + soldering piece pipe ø 10, ø 15 mm
Outlet pressure relieve valve
6,8 bar
Intermediate pressure relieve valve
17 bar
Pressure relieve valve pipe dimension
ø 15 mm
Regulatory status
Complies with Medical Devices Directive 93/42/EEC, EN ISO 7396-1 (Central Gas Supply Systems), EN 60601-1-2 (Electromagnetic compatibility), present SIS HB 370 and HTM 02-01